Myrra 24 V ac 2 Output Through Hole PCB Transformer, EN 61558-2-6 2.3 VA
- RS Stock No.:
- 173-9838
- Mfr. Part No.:
- 44168
- Manufacturer:
- Myrra
The image is for reference only, please refer to product details and specifications
Currently unavailable
Sorry, we don't know when this will be back in stock.
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
HK$47.40
- RS Stock No.:
- 173-9838
- Mfr. Part No.:
- 44168
- Manufacturer:
- Myrra
Specifications
Product overview and Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Myrra | |
| Product Type | PCB Transformer | |
| Secondary Voltage | 24 V ac | |
| Primary Voltage | 230 V ac | |
| Number of Outputs | 2 | |
| Length | 32.6mm | |
| Width | 27.6 mm | |
| Depth | 29.8mm | |
| Power | 2.3VA | |
| Weight | 70g | |
| Mount Type | Through Hole | |
| Isolation Voltage | 4kV | |
| Maximum Operating Temperature | 70°C | |
| Minimum Operating Frequency | 50Hz | |
| Standards/Approvals | EN 61558-2-6 | |
| Maximum Operating Frequency | 60Hz | |
| Select all | ||
|---|---|---|
Brand Myrra | ||
Product Type PCB Transformer | ||
Secondary Voltage 24 V ac | ||
Primary Voltage 230 V ac | ||
Number of Outputs 2 | ||
Length 32.6mm | ||
Width 27.6 mm | ||
Depth 29.8mm | ||
Power 2.3VA | ||
Weight 70g | ||
Mount Type Through Hole | ||
Isolation Voltage 4kV | ||
Maximum Operating Temperature 70°C | ||
Minimum Operating Frequency 50Hz | ||
Standards/Approvals EN 61558-2-6 | ||
Maximum Operating Frequency 60Hz | ||
RoHS Status: Exempt
- COO (Country of Origin):
- FR
Type EI 30 - 1 VA → 2.3 VA series 44000 transformers
From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable.
Features and Benefits:
• Professional safety transformers with insulation above 4000V.
• For installation on printed circuit boards (according to European grid).
• Coupling in series or parallel.
• Vacuum-filled with resin to ensure materials withstand aging.
• Unit and 100% control on automated line.
• Secondary voltages are nominal load voltages on resistive loads.
Encapsulated – Toroidal
Note
Fixing screws not provided
Approvals
UL, VDE
Standards
UL 94-V0; VDE 0551; IEC 742
Related links
- Myrra 12 V ac 2 Output PCB PCB Transformer, EN 61558-2-6 2.3 VA
- Myrra 18 V ac 2 Output PCB PCB Transformer, EN 61558-2-6 2.3 VA
- Myrra 6 V ac 2 Output Through Hole PCB Transformer, EN 61558-2-6 2.3 VA
- Myrra 24 V ac 2 Output Through Hole PCB Transformer, EN 61558-2-6 1.5 VA
- Myrra 24 V ac 2 Output Through Hole PCB Transformer, EN 61558-2-6 1 VA
- Myrra 24 V ac 2 Output Through Hole PCB Transformer UL 1585, EN 61558-2-6 30 VA
- Myrra 24 V ac 2 Output Through Hole PCB Transformer UL 1585, EN 60950 30 VA
- Myrra 24 V ac 2 Output PCB PCB Transformer EN 61558-2-6, UL 1585 0.6 VA