Gossen Metrawatt M507A Loop Impendence Tester, Loop Impedance Test Type 2 Wire 260V Hex Socket Cap
- RS Stock No.:
- 260-8281
- Mfr. Part No.:
- M507A
- Manufacturer:
- Gossen Metrawatt
Subtotal (1 unit)*
HK$8,266.50
FREE delivery for orders over HK$250.00
Stocked by manufacturer
- Ready to ship from 14 December 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | HK$8,266.50 |
*price indicative
- RS Stock No.:
- 260-8281
- Mfr. Part No.:
- M507A
- Manufacturer:
- Gossen Metrawatt
Specifications
Product overview and Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Gossen Metrawatt | |
| Test Equipment Type | Earth Loop Impedance Tester | |
| Loop Impedance Test Type | 2 Wire | |
| Product Type | Loop Impendence Tester | |
| Maximum Voltage Measurement | 260V | |
| PSC Display | No | |
| Display Type | OLED | |
| Battery Type | AAA | |
| Minimum Operating Temperature | 0°C | |
| Maximum Operating Temperature | 40°C | |
| Power Source | Battery Power Supply | |
| Weight | 360g | |
| Standards/Approvals | IEC 615571/3, EN 615573, IEC 610101/031, DIN EN 610101/031, VDE 04111/031, IEC 613261, DIN EN 60529, DIN EN 613261, DIN EN 615571/3, VDE 04701, VDE 04131/3 | |
| Safety Category Level | Hex Socket Cap | |
| Safety Category Voltage | 300V | |
| Select all | ||
|---|---|---|
Brand Gossen Metrawatt | ||
Test Equipment Type Earth Loop Impedance Tester | ||
Loop Impedance Test Type 2 Wire | ||
Product Type Loop Impendence Tester | ||
Maximum Voltage Measurement 260V | ||
PSC Display No | ||
Display Type OLED | ||
Battery Type AAA | ||
Minimum Operating Temperature 0°C | ||
Maximum Operating Temperature 40°C | ||
Power Source Battery Power Supply | ||
Weight 360g | ||
Standards/Approvals IEC 615571/3, EN 615573, IEC 610101/031, DIN EN 610101/031, VDE 04111/031, IEC 613261, DIN EN 60529, DIN EN 613261, DIN EN 615571/3, VDE 04701, VDE 04131/3 | ||
Safety Category Level Hex Socket Cap | ||
Safety Category Voltage 300V | ||
- COO (Country of Origin):
- CZ
Gossen-Metrawatt Loop Impendence Tester, 360g Weight, 260V Maximum Voltage Measurement - M507A
This loop impedance tester provides handheld measurements of earth loop impedance using a two-wire testing method. Designed for use by electricians for routine verification and fault diagnosis, it operates from battery power and displays results on an OLED screen. The instrument is intended for work under a safety category of CAT III and functions within typical site temperature ranges.
Features and Benefits:
• 2-wire loop test delivers clear earth loop assessment
• OLED display offers enhanced visibility for readings
• Battery power ensures portability on site
• CAT III safety rating enables mains-level testing
• 360g weight supports one-handed operation
• OLED display offers enhanced visibility for readings
• Battery power ensures portability on site
• CAT III safety rating enables mains-level testing
• 360g weight supports one-handed operation
Applications
• Suitable for on-site electrical installation verification
• Ideal for routine earth loop fault diagnosis
• Used with single-phase distribution circuits up to 260V
• Can be used for portable inspection by electricians
• Applicable in environments within 0 to 40°C operating temperature
• Ideal for routine earth loop fault diagnosis
• Used with single-phase distribution circuits up to 260V
• Can be used for portable inspection by electricians
• Applicable in environments within 0 to 40°C operating temperature
What power source does it use?
It runs on AAA batteries, allowing straightforward replacement.
What voltage range can it measure reliably?
It measures up to 260V maximum voltage for loop assessment.
Which safety category applies to its operation?
It is specified to operate at a CAT III safety level.
What standards and approvals does it meet?
It conforms to multiple standards including IEC 61557-1/3, EN 61557-3, IEC 61010-1, DIN EN 61010-1, VDE 0411/031, IEC 61326-1 and DIN EN 60529.
Related links
- Gossen Metrawatt M507B Loop Impendence Tester RCD Test Type AC Selective, RCD
- Megger LTW315-EU-BS Loop Impendence Tester 3 Wire 440V RCD Test
- Kewtech Corporation FC2000 Loop Impendence & RCD Combined Tester RCD Test Type
- Megger LTW325-EU-BS Loop Impendence & RCD Combined Tester RCD Test Type AC, RCD
- Megger LTW425-EU-BS Loop Impendence & RCD Combined Tester RCD Test Type AC, RCD
- Megger LRCD220-EN-BS Loop Impendence & RCD Combined Tester RCD Test Type AC
- Megger RCDT320-EN-BS RCD Tester RCD Test Type DC, RCD Test Current 1000 mA CAT
- Megger RCDT310-EN-BS RCD Tester RCD Test Type DC Selective RCD