Signal Conditioners | RS
Recently searched

    Signal Conditioners

    Signal conditioners are electronic devices used to modify and optimize electrical signals in various measurement and control systems. They are typically employed in situations where the electrical signals from sensors, transducers, or other sources need to be adjusted or conditioned to meet specific requirements.

    How do Signal Conditioners Work?

    The primary purpose of a signal conditioner is to ensure that the signals are suitable for further processing, transmission, or conversion by other devices or systems. Signal conditioners can perform a variety of functions depending on the specific application.

    What are the types of Signal Conditioning?

    Signal conditioners can be classified into several types based on their specific functions and the signals they process. Here are some common types of signal conditioners: Amplifiers: Amplifiers are signal conditioners used to amplify weak input signals. They increase the signal strength to a level suitable for further processing or transmission. Filters: Signal conditioners that incorporate filters are used to remove unwanted noise or interference from the input signals. Different types of filters, such as low-pass, high-pass, band-pass, or notch filters, are used based on the specific frequency ranges to be filtered. Linearizers: Linearizers are signal conditioners that compensate for nonlinearities in the input signal. They apply mathematical algorithms or lookup tables to linearize the output and provide a more linear response over the measurement range. Isolation Amplifiers: These signal conditioners provide electrical isolation between the input and output sides of a system. They protect sensitive measurement equipment from electrical noise, voltage spikes, and ground loops, ensuring accurate and reliable measurements. Converters: Signal conditioners known as converters are used to convert signals from one form to another. For example, analogue-to-digital converters (ADCs) convert analogue signals into digital form, while digital-to-analogue converters (DACs) convert digital signals into analogue form.

    Where are Signal Conditioners Used?

    Signal conditioners are widely used in industrial automation, process control, data acquisition systems, scientific research, and various other fields where accurate and reliable signal processing is essential. They play a crucial role in optimizing signal quality, reducing noise, and improving the overall performance of measurement and control systems.

    706 Products showing for Signal Conditioners

    Weidmüller
    Limit Value Switch
    Temperature
    -
    Relay
    1000°C
    ± 25mA
    24V dc
    -
    -
    -
    -
    -
    -
    -
    ACT20P
    Crouzet
    Temperature Converter
    RTD
    -
    Voltage
    0 → 100°C
    0 → 10V dc
    24V dc
    -
    DIN Rail Mount
    -5°C
    -5 → +55°C
    +55°C
    -
    -
    -
    Pepperl + Fuchs
    Passive Isolator
    Current
    -
    Current
    50 mA, 0 → 20 mA, 4 → 20mA
    0 → 20 mA, 4 → 20mA
    2.2 → 30V dc
    -
    DIN Rail Mount
    -25°C
    -25 → +70°C
    +70°C
    -
    -
    S1SL
    Phoenix Contact
    Isolation Amplifier
    NAMUR Sensor, Switch
    -
    Transistor
    -
    -
    19.2 → 30V dc
    -
    -
    -20°C
    -20 → +60°C
    +60°C
    -
    -
    3RS7006
    PR Electronics
    MV Converter
    Voltage
    -
    Current
    -40 → +100mV
    0 → 20mA
    19.2 → 28.8V dc
    -
    DIN Rail Mount
    -20°C
    -20 → +60°C
    +60°C
    -
    -
    2
    PR Electronics
    Pulse Isolator
    NAMUR Sensor, Switch
    -
    NPN, Relay
    -
    -
    19.2 → 31.2V dc
    ATEX, IECEx
    -
    -
    -
    -
    -
    -
    9200
    Weidmüller
    Signal Isolator
    Current
    -
    Current
    4 → 20mA
    4 → 20mA
    19.2 → 31.2V
    IECEx
    DIN Rail Mount
    -20°C
    -20 → +60°C
    +60°C
    -
    -
    ACT20X
    Schneider Electric
    -
    Current, Voltage
    -
    -
    4 → 20mA
    -
    24V
    IECEx
    Clip-On
    -40°C
    -40 → +80°C
    +85°C
    Yes
    Green Premium
    Harmony Analog
    Turck
    Frequency Transducer
    Frequency
    -
    Relay
    3-Wire Input - 12 V dc, NAMUR Input - 8.2 V dc
    = 30 VDC or = 250 VAC
    10 → 30V dc
    Ex, SIL, UL
    -
    -
    -
    -
    -
    -
    IM(X)12
    PR Electronics
    Pulse Isolator
    NAMUR Sensor, Switch
    -
    NPN, Relay
    -
    -
    19.2 → 31.2V dc
    ATEX, IECEx
    -
    -
    -
    -
    -
    -
    9200
    Kubler
    Signal Splitter
    HTL, RS-422
    -
    HTL, RS-422, TTL
    250 kHz, 10 → 30V
    30 mA, 12 → 30V
    12 → 30V dc
    -
    DIN Rail Mount
    -20°C
    -20 → +60°C
    +60°C
    -
    -
    -
    JM CONCEPT
    Converter Strain Gauge
    Strain Gauge
    -
    Current, Voltage, Relay
    Standard scales: ±18 mv; ±35mv ; ±75mv ; ±150mv, ±300mv ; ±600mv ; ±1V ; ±2V,
    -
    22 → 240 V dc, 90 → 230V ac
    -
    -
    -10°C
    -10 → +60°C
    +60°C
    -
    -
    TELIS 1000
    WAGO
    Current Signal Converter
    Current
    -
    RS-485
    0 - 50A
    -
    24V dc
    -
    -
    -
    -
    -
    -
    -
    857
    Phoenix Contact
    Converter
    -
    -
    -
    -
    -
    24V dc
    ATEX
    -
    -
    -
    -
    -
    -
    PSI
    Weidmüller
    Temperature Converter
    Temperature
    -
    Current
    850°C
    4 → 20mA
    35V
    ATEX, IECEx
    -
    -
    -
    -
    -
    -
    ACT20M
    Weidmüller
    Signal Converter
    Current
    -
    Voltage
    4 → 20mA
    0 → 10V dc
    30V dc
    ATEX, IECEx
    -
    -
    -
    -
    -
    -
    ACT20P
    Motrona
    Signal Splitter
    Pulse
    -
    Analogue
    10 → 30V dc
    24V dc
    10 → 30V dc
    -
    -
    -
    -
    -
    -
    -
    EV
    BALLUFF
    Switching Amplifier
    PNP
    -
    -
    10000Hz
    -
    10 → 30V dc
    -
    -
    -
    -
    -
    -
    -
    BAE
    Weidmüller
    Signal Isolator
    Current
    -
    Current
    4 → 20mA
    4 → 20mA
    19.2 → 31.2V
    IECEx
    DIN Rail Mount
    -20°C
    -20 → +60°C
    +60°C
    -
    -
    ACT20X
    JM CONCEPT
    AC Current Converter
    AC Current
    -
    Current, Voltage, Relay
    0 → 5A
    -
    22 → 240 V dc, 90 → 230V ac
    -
    DIN Rail
    -10°C
    -10 → +60°C
    +60°C
    -
    -
    ULCOS 600
    Results per page