SMC Vacuum Generator, 1 mm nozzle, -91 kPa 44 L/min, ZK2 series

Subtotal (1 unit)*

HK$2,286.00

Add to Basket
Select or type quantity
Stocked by manufacturer
  • Ready to ship from 19 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +HK$2,286.00

*price indicative

RS Stock No.:
392-165
Mfr. Part No.:
ZK2C10J5PL1A-06
Manufacturer:
SMC
Find similar products by selecting one or more attributes.
Select all

Brand

SMC

Maximum Suction Flow

44L/min

Product Type

Vacuum Generator

Maximum Vacuum Pressure

-91kPa

Nozzle Diameter

1mm

Series

ZK2

Silencer

Yes

Minimum Operating Temperature

0°C

Maximum Supply Pressure

0.6MPa

Vacuum Port Size

6 mm

Maximum Operating Temperature

+50°C

Standards/Approvals

RoHS, CE

Exhaust Port Size

6 mm

SMC ZK2 Series Vacuum Generator, 44L/min Maximum Suction Flow, -91kPa Maximum Vacuum Pressure - ZK2C10J5PL1A-06


This vacuum generator is a Compact pneumatic ejector designed for automated pick-and-place and handling systems in industrial settings. It combines a two-stage ejector with integrated valves and a pressure sensor option to provide controlled suction for small to medium payloads while operating from a common manifold exhaust.

Features & Benefits


• Max suction flow 44L/min delivers efficient part transfer
• Maximum vacuum pressure -91kPa enables secure grip on components
• Nozzle diameter 1mm supports fine-detail handling
• Supply pressure up to 0.6MPa permits robust plant integration
• Built-in silencer reduces exhaust noise to 66dB for quieter operation

Applications


• Suitable for vacuum gripping of electronic components in pick-and-place machines
• Ideal for mechanical assembly tasks requiring precise suction control
• Used with automated conveyors for component transfer and positioning
• Can be used for testing rigs needing repeatable vacuum application

What electrical supply is required to operate the unit?


It runs from a DC supply between 12 and 24V with ±10% tolerance and accepts up to 10% ripple (p-p).

How is the vacuum level monitored and output to automation controls?


An analogue pressure sensor option provides 1 to 5V output proportional to vacuum from 0 to -101kPa with approximately 1kΩ output impedance.

What environmental limits should be observed during installation?


Operate within 0 to 50°C and 35 to 85% RH without condensation

storage extends to −20 to 70°C with no freezing.

How is serviceability addressed for the suction path?


A nominal 30μm suction filter with 510mm² filtration area is fitted to protect the ejector from particulate ingress.