Select all | Attribute | Value |
|---|---|---|
| Brand | Time Electronics | |
| Resolution | 0.1 °C, 0.1 °F | |
| Calibrator Type | Thermocouple Calibrator | |
| Best Accuracy | 0.2 °C | |
| Thermocouple Type | B, E, J, K, N, R, S, T | |
| Temperature Scale | Centigrade, Fahrenheit | |
| B Type Thermocouple Maximum Temperature | +1800°C | |
| B Type Thermocouple Minimum Temperature | 110°C | |
| E Type Thermocouple Maximum Temperature | +400°C | |
| E Type Thermocouple Minimum Temperature | 50°C | |
| J Type Thermocouple Maximum Temperature | 580°C | |
| K Type Thermocouple Maximum Temperature | +750°C | |
| K Type Thermocouple Minimum Temperature | -200°C | |
| Model Number p | 1090 | |
| T Type Thermocouple Temperature Range | -200 → +400 °C | |
| Weight | 1.2kg | |
| Height | 235mm | |
| J Type Thermocouple Temperature Range | -200 → +580 °C | |
| R Type Thermocouple Temperature Range | +50 → +1750 °C | |
| S Type Thermocouple Temperature Range | -50 → +1750 °C | |
| Dimensions | 75 x 150 x 235mm | |
| E Type Thermocouple Temperature Range | -50 → +400 °C | |
| K Type Thermocouple Temperature Range | -200 → +750 °C | |
| Length | 75mm | |
| Width | 150mm | |
| B Type Thermocouple Temperature Range | +110 → +1800 °C | |
| Select all | ||
|---|---|---|
Brand Time Electronics | ||
Resolution 0.1 °C, 0.1 °F | ||
Calibrator Type Thermocouple Calibrator | ||
Best Accuracy 0.2 °C | ||
Thermocouple Type B, E, J, K, N, R, S, T | ||
Temperature Scale Centigrade, Fahrenheit | ||
B Type Thermocouple Maximum Temperature +1800°C | ||
B Type Thermocouple Minimum Temperature 110°C | ||
E Type Thermocouple Maximum Temperature +400°C | ||
E Type Thermocouple Minimum Temperature 50°C | ||
J Type Thermocouple Maximum Temperature 580°C | ||
K Type Thermocouple Maximum Temperature +750°C | ||
K Type Thermocouple Minimum Temperature -200°C | ||
Model Number p 1090 | ||
T Type Thermocouple Temperature Range -200 → +400 °C | ||
Weight 1.2kg | ||
Height 235mm | ||
J Type Thermocouple Temperature Range -200 → +580 °C | ||
R Type Thermocouple Temperature Range +50 → +1750 °C | ||
S Type Thermocouple Temperature Range -50 → +1750 °C | ||
Dimensions 75 x 150 x 235mm | ||
E Type Thermocouple Temperature Range -50 → +400 °C | ||
K Type Thermocouple Temperature Range -200 → +750 °C | ||
Length 75mm | ||
Width 150mm | ||
B Type Thermocouple Temperature Range +110 → +1800 °C | ||
RoHS Status: Exempt
- COO (Country of Origin):
- GB
Temperature & mV/mA Calibrator 1090
Displays in selectable units in °C/°F, uV/m
Large backlit super-twist LCD display, 7.5 mm digits
Sealed membrane keypad
Automatic or manual cold junction compensation
Memory storage of frequently used values
Sturdy carrying case with test lead compartment
Equivalent converted uV/Pt 100 resistance can be displayed on both source & measure
Rechargeable battery 50+ hrs use. Auto power save button
Auto step function with configurable step time
24V process loop drive mode
Note
Supplied with
Related links
- Schneider Electric Temperature Temperature Probe
- Fluke Temperature Pencil Temperature Probe, +60 °C Max
- WIKA Temperature Bath for Use with Temperature Probe
- Digitron Temperature General Temperature Probe, +110 °C Max
- Digitron Temperature Air Temperature Probe, +110 °C Max
- Phoenix Contact MCR Temperature Transmitter Temperature Input, 30 V dc
- Phoenix Contact MACX Temperature Transmitter Temperature Input, 36 V dc
- Phoenix Contact MACX Temperature Transmitter Temperature Input, 30 V dc