Phoenix Contact DEK-OE- 5DC/ 48DC/100 Solid State Interface Relay 3V dc, 48 V dc DIN Rail Screw

Subtotal (1 unit)*

HK$745.30

Add to Basket
Select or type quantity
In Stock
  • Plus 34 unit(s) shipping from 16 November 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +HK$745.30

*price indicative

RS Stock No.:
801-8567
Mfr. Part No.:
2940223
Manufacturer:
Phoenix Contact
Find similar products by selecting one or more attributes.
Select all

Brand

Phoenix Contact

Series

DEK-OE- 5DC/ 48DC/100

Product Type

Solid State Interface Relay

Maximum Operating Temperature

60°C

Minimum Operating Temperature

-20°C

Switching Voltage

3V dc, 48V dc

Mount Type

DIN Rail

Switching Current

1A

Terminal Type

Screw

Output Type

Electronic

LED Display

Yes

Standards/Approvals

IEC 60947-5-1

Rise Time

20μs

Isolation Voltage

2.5kV ac

Length

56mm

Depth

56mm

Width

6.2mm

COO (Country of Origin):
CN

DEK-OE- 5DC/ 48DC/100 2940223


Phoenix Contact DEK-OE Solid State Relay Terminal Blocks


Solid-state relay terminal blocks from the Phoenix Contact interface relay module series, with integrated input circuit, output protective circuit and status indicator. Mountable on DIN rail NS 35/7,5, reducing space these units are 6.2mm wide and offer labelling and mounting with user-friendly modular terminal blocks.

This range of interface modules gives you a great choice of easy connection technology. The terminal blocks act as the interface between your automation equipment and system peripherals.

Features and Benefits:


• EB-DIK insertion bridges

• Zero voltage switch at AC output

• Wear-free switching of up to 24 V DC/10 A or 240 V AC/800 mA

• Actuator version available

• Yellow LED status indicator

• 6.2 x 80 x 56 mm dimensions

• Reverse polarity protection

• Free-wheeling diode protection

Applications:


DEK-OE solid-state relay blocks are used in many different applications not limited to power amplification, electrical isolation or for using for voltage adjustment of frequency varying voltage levels.

Zero Voltage Relays


Note

Temperature can affect current rating; please consult the data sheet for potential derating.