Schneider Electric Multi9 Series Residual Current Circuit Breaker, 40A, 2-Pole, 26 mA, Type A, 10 kA
- RS Stock No.:
- 211-2465
- Mfr. Part No.:
- M9R81240
- Manufacturer:
- Schneider Electric
Currently unavailable
We don't know if this item will be back in stock, RS intend to remove it from our range soon.
- RS Stock No.:
- 211-2465
- Mfr. Part No.:
- M9R81240
- Manufacturer:
- Schneider Electric
Specifications
Product overview and Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 40A | |
| Number of Poles | 2 | |
| Series | Multi9 | |
| Range | Multi9 | |
| Trip Sensitivity | 26mA | |
| Mount Type | DIN Rail | |
| Tripping Characteristics | Type A | |
| Terminal Type | Screw | |
| Standards/Approvals | RoHS, REACH | |
| Depth | 60mm | |
| Width | 36mm | |
| Height | 81mm | |
| Breaking Capacity | 10kA | |
| Tripping Mechanism | Electromagnetic | |
| Earth Leakage Protection Type | Type A | |
| Reset Actuator Type | Toggle Switch | |
| Break Time | Instantaneous | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 40A | ||
Number of Poles 2 | ||
Series Multi9 | ||
Range Multi9 | ||
Trip Sensitivity 26mA | ||
Mount Type DIN Rail | ||
Tripping Characteristics Type A | ||
Terminal Type Screw | ||
Standards/Approvals RoHS, REACH | ||
Depth 60mm | ||
Width 36mm | ||
Height 81mm | ||
Breaking Capacity 10kA | ||
Tripping Mechanism Electromagnetic | ||
Earth Leakage Protection Type Type A | ||
Reset Actuator Type Toggle Switch | ||
Break Time Instantaneous | ||
- COO (Country of Origin):
- ES
The Schneider Electric Multi 9 GFP series is a Residual current circuit breaker (RCCB) with a Type A-SI Earth-leakage protection class. They are used for control and disconnection of electric circuits, protection of people against electric shock by direct and indirect contacts, protection of installations against insulation faults, enhanced continuity of supply, during a series of close lightning strokes.
Enhanced earth leakage protection
Protection of installations against insulation faults
Related links
- Schneider Electric Multi9 Series Residual Current Circuit Breaker 2-Pole Type A, 10 kA
- Schneider Electric Multi9 Series Residual Current Circuit Breaker 2-Pole Type A, 10 kA
- Schneider Electric Multi9 Series Residual Current Circuit Breaker 4-Pole Type A, 10 kA
- Schneider Electric Multi9 Series Residual Current Circuit Breaker 4-Pole Type A, 10 kA
- Schneider Electric GFP Series Residual Current Circuit Breaker 2-Pole Type A-SI, 1500 A 230V ac
- Schneider Electric Multi9 Series Residual Current Circuit Breaker 2-Pole Type A, 10 kA
- Schneider Electric Multi9 Series Residual Current Circuit Breaker 4-Pole Type A, 1500 A
- Schneider Electric Multi9 Series Residual Current Circuit Breaker 4-Pole Type A, 10 kA