Teledyne LeCroy CP030A Current Probe, AC/DC Type, 50MHz
- RS Stock No.:
- 878-7604
- Mfr. Part No.:
- CP030A
- Manufacturer:
- Teledyne LeCroy
Discontinued product
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
HK$71,067.70
- RS Stock No.:
- 878-7604
- Mfr. Part No.:
- CP030A
- Manufacturer:
- Teledyne LeCroy
- COO (Country of Origin):
- JP
Teledyne LeCroy Current Probes
Teledyne LeCroy current probes make accurate and reliable AC, DC and impulse current measurements without requiring the breaking of a circuit or the insertion of a shunt. This capability is based on a combination of Hall effect and transformer technology. Many current probes require external power supplies or amplifiers to display a waveform on the oscilloscope screen. LeCroy current probes are powered through the LeCroy ProBus® connection and require no additional hardware. Along with providing power, the ProBus connection allows the current probe and oscilloscope to communicate, resulting in current waveforms automatically displayed on screen in Amps, and calculated power traces scaled correctly in Watts. This integration also allows for Degauss and Autozero functions to be carried out directly from the oscilloscope with the press of a button. Applications of LeCroy current probes include use in the design and test of switching power supplies, motor drives, electric vehicles and uninterruptible power supplies.
Features and Benefits:
Rise time (typical) <7 ns (CP030) < 3.5 ns (CP031), <35 ns (CP150), < 175 ns (CP500)
Minimum sensitivity 1mA/div (CPO30A & CPO31A), 10 mA/div (CP030 & CP031), 100 mA/div (CP150 & CP500)
AC noise < 2.5 mA (CP030 & CP031), <25 mA (CP150), 25 mA (CP500)
Coupling AC, DC, GND
Cable length 1.5 m (CP030 & CP031), 2m (CP150), 6m (CP500)
Weight 240g (CP030 & CP031), 500g (CP150), 630g (CP500)
Interface ProBus, 1 MΩ only (requires AP-1M for use with 50Ω input only oscilloscopes)
Usage environment indoors
Operating temperature 0 °C to 40 °C
Maximum relative humidity 80%
Maximum altitude 2000m
Minimum sensitivity 1mA/div (CPO30A & CPO31A), 10 mA/div (CP030 & CP031), 100 mA/div (CP150 & CP500)
AC noise < 2.5 mA (CP030 & CP031), <25 mA (CP150), 25 mA (CP500)
Coupling AC, DC, GND
Cable length 1.5 m (CP030 & CP031), 2m (CP150), 6m (CP500)
Weight 240g (CP030 & CP031), 500g (CP150), 630g (CP500)
Interface ProBus, 1 MΩ only (requires AP-1M for use with 50Ω input only oscilloscopes)
Usage environment indoors
Operating temperature 0 °C to 40 °C
Maximum relative humidity 80%
Maximum altitude 2000m
Applications:
- Automotive
- Power Applications
- Motor drive development
- Product design applications
Teledyne LeCroy's current probes are used in a wide array of applications in a multitude of different industries. The probe is a vital piece of equipment for any professional who is designing, testing or repairing electronic equipment. Some of the most common are;
- Testing switching power supplies
- Motor drives
- Electric vehicles
- Uninterruptable power supplies
Compatibility:
Why Teledyne LeCroy?
Teledyne LeCroy oscilloscopes and probes have been designed, manufactured and tested to the highest standards. This ensures high reliability and quality. In the unlikely event, you experience any problems all Teledyne LeCroy digital oscilloscopes are covered by a 3-year manufactures warranty and probes a 1-year warranty.
Note
The CP030 ( 801-4858 ) & CP031 ( 724-0911 ) are compatible with LeCroy X-Stream oscilloscopes running firmware version 4.3.1.1 or greater. Their Minimum Sensitivity is 10mA/div compared with 1mA/div for CPO30A ( 878-7604 ) & CPO31A ( 878-7607 ). The maximum conductor size for these four models is 5mm od. CP150 ( 801-4855 ) & CP500 ( 724-0918 ) have Minimum Sensitivity 100mA/div and maximum conductor size 20mm od. Teledyne LeCroy current probes have a small form factor which makes probing easier on a crowded compact board.
Teledyne LeCroy Current Probe
The Teledyne LeCroy 1.5m current probe is a state of the art device that does not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall Effect and transformer technology, this current probe is ideal for making accurate AC, DC, and impulse current measurements.
Note:
The CP030 (801-4858 ) andCP031 (724-0911 ) are compatible with LeCroy X-stream oscilloscopes running firmware version 4.3.1.1 or greater. Their minimum sensitivity is 10mA/div compared with 1mA/div for CPO30A (878-7604 ) and CPO31A (878-7607 ). The maximum conductor size for these four models is 5mm OD. CP150 (801-4855 ) and CP500 (724-0918 ) have minimum sensitivity 100mA/div and maximum conductor size 20mm OD. Teledyne LeCroy current probes have a small form factor that makes probing easier on a crowded compact board.
Note:
The CP030 (801-4858 ) andCP031 (724-0911 ) are compatible with LeCroy X-stream oscilloscopes running firmware version 4.3.1.1 or greater. Their minimum sensitivity is 10mA/div compared with 1mA/div for CPO30A (878-7604 ) and CPO31A (878-7607 ). The maximum conductor size for these four models is 5mm OD. CP150 (801-4855 ) and CP500 (724-0918 ) have minimum sensitivity 100mA/div and maximum conductor size 20mm OD. Teledyne LeCroy current probes have a small form factor that makes probing easier on a crowded compact board.
Features and Benefits
ProBus active probe interface with automatic scaling in A/div
Autozero and degauss capabilities built-into instruments user interface
30 Arms continuous current
50 Apeak current
50MHz bandwidth
1mA/div sensitivity
Compatible with the DSC015
Autozero and degauss capabilities built-into instruments user interface
30 Arms continuous current
50 Apeak current
50MHz bandwidth
1mA/div sensitivity
Compatible with the DSC015
Applications
Switching power supplies
Motor drives
Electric vehicles
Uninterruptible power supplies
Motor drives
Electric vehicles
Uninterruptible power supplies
Certificate No.
CAT I
Attribute | Value |
---|---|
Probe Type | AC/DC |
Bandwidth | 50MHz |
Model Number p | CP030A |
Safety Category Level | CAT I |
Safety Category Voltage | 300V |
Current | 30A |
Safety Category | CAT I 300V |