Druck DPI 615 0bar to 2bar Pressure Calibrator
- RS Stock No.:
- 532-7619
- Mfr. Part No.:
- I615SPC-07G-4025
- Manufacturer:
- Druck
The image is for reference only, please refer to product details and specifications
Price Each**
HK$75,013.78
5 In stock for delivery within 3 working days*
* Delivery dates may change based on your chosen quantity and delivery address.
FREE delivery for orders over HK$850.00
Units | Per unit |
---|---|
1 + | HK$75,013.78 |
**price indicative
- RS Stock No.:
- 532-7619
- Mfr. Part No.:
- I615SPC-07G-4025
- Manufacturer:
- Druck
RoHS Status: Not Applicable
- COO (Country of Origin):
- GB
Druck Pressure Calibrator - DPI615 - IS, Intrinsically Safe
Druck's DPI615 - IS pressure calibrator is not only portable, easy to use and intrinsically safe, but it is designed for pressure ranges from 2.5 mbar to 700 bar. Druck's range of pressure calibrators are very easy to use, any technician can use the DPI615 calibrator without any previous formal training. The key to the simplicity of use is mainly because of the task-menu, this function allows users to use modes such as P-I, switch test and leak test at the touch of a button. Constructed of a robust, rugged and weather-proof material and design, styled in such a way that the pressure pump can be operated, and test leads connected without compromising the visibility of the large dual parameter display. Featuring a built-in continuity tester and the mA step and ramp outputs contribute to extending the capabilities to include commissioning and maintenance of control loops. Predominantly used for pressure calibration, the DPI615 can be used within a multitude of applications including maintenance and commissioning.
Features & Benefits
These intrinsically safe pressure calibrators are certified to European and North American standards for use in hazardous areas
Ranges between -14.7 to 6000 psi
A task-driven user interface facilitates an easy set-up of calibration, switch testing and leak testing 4 to 20mA simulation, relief valve testing, data logging and ambient temperature recording modes
Pressure range accuracy: ±0.025% full scale of all ranges
Integral combined pressure/vacuum pump
Dual readout: input and output
4-20mA loop test: auto step and ramp
RS232 interface and fully documenting version
Pressure and current displayed simultaneously
Current and voltage measurement
26 Selectable pressure units
Two-way PC communication for transferring procedures and results
Pressure/vacuum pump -850mbar to 20bar
Ranges between -14.7 to 6000 psi
A task-driven user interface facilitates an easy set-up of calibration, switch testing and leak testing 4 to 20mA simulation, relief valve testing, data logging and ambient temperature recording modes
Pressure range accuracy: ±0.025% full scale of all ranges
Integral combined pressure/vacuum pump
Dual readout: input and output
4-20mA loop test: auto step and ramp
RS232 interface and fully documenting version
Pressure and current displayed simultaneously
Current and voltage measurement
26 Selectable pressure units
Two-way PC communication for transferring procedures and results
Pressure/vacuum pump -850mbar to 20bar
Did you know?
The "IS" in the name of a pressure calibrator stands for intrinsically safe, if an item is intrinsically safe it means that it is incapable of releasing sufficient electrical and thermal energy under normal or abnormal conditions. This results in the item not being able to cause ignition of a specific hazardous atmospheric mixture in its most easily ignited concentration.
What's included with this kit?
Batteries
Carrying case
Test leads
User guide
Calibration certificate
Pressure calibrator
Carrying case
Test leads
User guide
Calibration certificate
Pressure calibrator
Group and Category
ll 1 G EEX ia llC T4
Druck Pressure Calibrator, Current Loop Measurement, 300mm Length - I615SPC-07G
This pressure calibrator by Druck is a reliable and safe device reliable for measuring pressure in hazardous areas. With its intrinsically safe and ATEX certification, it is designed to handle high pressure measurements with ease. The portable nature of this calibrator makes it versatile for various applications.
Features & Benefits
• Data logging feature for easy record keeping
• Intrinsically safe design for hazardous areas
• Leak testing functionality for accurate measurements
• Gauge pressure calibration for precise readings
• Lightweight at only 3 kg for portability
• Easy-to-use design for reliable results
• Intrinsically safe design for hazardous areas
• Leak testing functionality for accurate measurements
• Gauge pressure calibration for precise readings
• Lightweight at only 3 kg for portability
• Easy-to-use design for reliable results
Applications
• Used for pressure calibration in hazardous environments
• Ideal for leak testing applications
• Suitable for data logging in pressure measurement
• Can be used for gauge pressure calibration
• Ideal for leak testing applications
• Suitable for data logging in pressure measurement
• Can be used for gauge pressure calibration
Can it handle high pressure measurements?
Yes, the Druck pressure calibrator is designed to handle pressure measurements up to 2 bar with ease.
Will it work in hazardous areas?
Yes, the calibrator is intrinsically safe and ATEX certified, making it suitable for use in hazardous environments.
Is data logging possible with this device?
Yes, the pressure calibrator features a data logging function for easy record keeping.
Attribute | Value |
---|---|
Maximum Pressure Measurement | 2bar |
Minimum Pressure Measurement | 0bar |
Pressure Port Type | Gauge |
Data Logging | Yes |
Model Number p | DPI 615 |
Intrinsically Safe | Yes |
Current Loop Measurement | Yes |
Leak Testing | Yes |
Maximum Operating Temperature | +50°C |
Minimum Operating Temperature | -10°C |
Weight | 3kg |
Dimensions | 300 x 170 x 140mm |
Height | 140mm |
Length | 300mm |
Hazardous Area Certification | ATEX |
Width | 170mm |