Fluke calibration 8808A/TL 240V 8808A Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac
- RS Stock No.:
- 260-2715
- Mfr. Part No.:
- FLUKE 8808A/TL 240V
- Manufacturer:
- Fluke calibration
Subtotal (1 unit)*
HK$12,620.80
FREE delivery for orders over HK$250.00
- Ready to ship from 19 October 2026
Units | Per unit |
|---|---|
| 1 + | HK$12,620.80 |
*price indicative
- RS Stock No.:
- 260-2715
- Mfr. Part No.:
- FLUKE 8808A/TL 240V
- Manufacturer:
- Fluke calibration
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke calibration | |
| Multimeter Type | Bench | |
| Product Type | Digital Multimeter | |
| Model Number | 8808A/TL 240V | |
| Display Type | Digital | |
| Resistance Resolution | 1mΩ | |
| Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Frequency, Resistance, Temperature | |
| Maximum Resistance Measurement | 0.1GΩ | |
| Maximum DC Voltage Measurement | 1kV dc | |
| Maximum DC Current Measurement | 10A dc | |
| Maximum AC Current Measurement | 10A ac | |
| Maximum AC Voltage Measurement | 750V ac | |
| True RMS | Yes | |
| DC Current Accuracy | 0.02 % rdg | |
| AC Voltage Accuracy | ±0.2 % rdg | |
| DC Voltage Accuracy | ±0.015 % rdg + 0.003 | |
| AC Current Accuracy | ±0.3 % rdg | |
| DC Voltage Resolution | 1 μV | |
| DC Current Resolution | 1nA ac | |
| AC Current Resolution | 100μA ac | |
| AC Voltage Resolution | 1μV | |
| Maximum Frequency | 1MHz | |
| Resistance Measurement Accuracy | 0.02 % rdg + 0.003 % range | |
| Minimum Operating Temperature | 0°C | |
| Weight | 2.1kg | |
| Series | 8808A | |
| Width | 217mm | |
| Length | 297mm | |
| Height | 88mm | |
| Standards/Approvals | ANSI/ISA 61010-1 (S82.02.01):2004, AN/CSA C22.2, EN 61010-1:2001, UL 61010-1:2004 | |
| Safety Category Level | Connector Bracket, Joint | |
| Safety Category Voltage | 1000V dc | |
| Select all | ||
|---|---|---|
Brand Fluke calibration | ||
Multimeter Type Bench | ||
Product Type Digital Multimeter | ||
Model Number 8808A/TL 240V | ||
Display Type Digital | ||
Resistance Resolution 1mΩ | ||
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Frequency, Resistance, Temperature | ||
Maximum Resistance Measurement 0.1GΩ | ||
Maximum DC Voltage Measurement 1kV dc | ||
Maximum DC Current Measurement 10A dc | ||
Maximum AC Current Measurement 10A ac | ||
Maximum AC Voltage Measurement 750V ac | ||
True RMS Yes | ||
DC Current Accuracy 0.02 % rdg | ||
AC Voltage Accuracy ±0.2 % rdg | ||
DC Voltage Accuracy ±0.015 % rdg + 0.003 | ||
AC Current Accuracy ±0.3 % rdg | ||
DC Voltage Resolution 1 μV | ||
DC Current Resolution 1nA ac | ||
AC Current Resolution 100μA ac | ||
AC Voltage Resolution 1μV | ||
Maximum Frequency 1MHz | ||
Resistance Measurement Accuracy 0.02 % rdg + 0.003 % range | ||
Minimum Operating Temperature 0°C | ||
Weight 2.1kg | ||
Series 8808A | ||
Width 217mm | ||
Length 297mm | ||
Height 88mm | ||
Standards/Approvals ANSI/ISA 61010-1 (S82.02.01):2004, AN/CSA C22.2, EN 61010-1:2001, UL 61010-1:2004 | ||
Safety Category Level Connector Bracket, Joint | ||
Safety Category Voltage 1000V dc | ||
- COO (Country of Origin):
- CN
Fluke 8808A Series Multimeter, 1000V Safety Category Voltage, 10A Maximum DC Current Measurement - FLUKE 8808A/TL 240V
Features and Benefits:
• 1μV DC resolution facilitates detection of very small voltage changes
• 10A AC/DC current measurement supports power and load testing
• 100 mΩ low‑resistance range allows sensitive contact‑resistance checks
• 1 kV DC maximum rating permits high‑voltage component evaluation
• ±0.3% AC current accuracy ensures reliable alternating‑current readings
Applications
• Ideal for calibration laboratories requiring fine DC resolution
• Used with temperature sensors for thermal characterisation
• Can be used for capacitor testing during quality inspection
• Suitable for frequency response checks up to 440 Hz
What safety categories and approvals does it meet?
How does the display and form factor support bench use?
What are the environmental operating constraints?
What measurement resolutions are available for resistance and AC voltage?
Related links
- Fluke calibration 8808A/SU 8808A Bench Digital Multimeter True RMS 10 A dc, 750 V ac
- RS PRO RSDM3055A Bench Digital Multimeter True RMS 10 A dc, 750 V ac
- RS PRO IDM8351 Bench Digital Multimeter True RMS 10 A dc, 750 V ac
- RS PRO RSDM3055 Bench Digital Multimeter True RMS 10 A dc, 750 V ac
- Keithley 2010 Bench Digital Multimeter True RMS 750 V ac
- BK Precision 5493C Bench Digital Multimeter True RMS 10 A dc, 750 V ac
- RS PRO RSDM3045X Bench Digital Multimeter True RMS 10 A dc, 750 V ac
- BK Precision 2831E Bench Digital Multimeter True RMS 20 A dc, 750 V ac