Fluke 789 Multi-Function Calibrator, 30 mA, 1000V ac 50 mm 203 mm 100mm
- RS Stock No.:
- 447-7707
- Distrelec Article No.:
- 176-49-395
- Mfr. Part No.:
- FLUKE-789
- Manufacturer:
- Fluke
Subtotal (1 unit)*
HK$13,983.30
FREE delivery for orders over HK$250.00
Temporarily out of stock
- Shipping from 02 June 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | HK$13,983.30 |
*price indicative
- RS Stock No.:
- 447-7707
- Distrelec Article No.:
- 176-49-395
- Mfr. Part No.:
- FLUKE-789
- Manufacturer:
- Fluke
Specifications
Product overview and Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Multi-Function Calibrator | |
| Maximum Voltage Measurement | 1000V ac | |
| Accuracy | ±0.2 % | |
| Port Connections | HART | |
| Battery Life | 140h | |
| Maximum Current Measurement | 30mA | |
| Battery Type | AA | |
| Power Source | Battery | |
| Safety Category Level | CAT IV, CAT III | |
| Safety Category Voltage | 1000V ac | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 55°C | |
| Height | 50mm | |
| Width | 100mm | |
| Standards/Approvals | IEC 61010-1 | |
| Hazardous Area Certification | No | |
| Weight | 610g | |
| Length | 203mm | |
| Resolution | 1 mA | |
| Model Number | 789 | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Multi-Function Calibrator | ||
Maximum Voltage Measurement 1000V ac | ||
Accuracy ±0.2 % | ||
Port Connections HART | ||
Battery Life 140h | ||
Maximum Current Measurement 30mA | ||
Battery Type AA | ||
Power Source Battery | ||
Safety Category Level CAT IV, CAT III | ||
Safety Category Voltage 1000V ac | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 55°C | ||
Height 50mm | ||
Width 100mm | ||
Standards/Approvals IEC 61010-1 | ||
Hazardous Area Certification No | ||
Weight 610g | ||
Length 203mm | ||
Resolution 1 mA | ||
Model Number 789 | ||
RoHS Status: Exempt
- COO (Country of Origin):
- US
Fluke Multi-Function Calibrator, 0.02% Accuracy, 1000V Maximum Voltage Measurement - FLUKE-789
This multi-function calibrator combines a safety-rated digital multimeter with mA loop sourcing and simulation for field and workshop diagnostics. It measures volts, current, resistance and frequency while providing mA sourcing, simulation and loop power options, enabling troubleshooting and calibration of current-loop instrumentation in industrial settings.
Features & Benefits
• 0.02%+2 precision accuracy for demanding calibration tasks
• 1000V true-rms measurement capability for high-voltage testing
• 30mA maximum current with 1mA resolution for fine loop adjustments
• AA battery power with 140h typical measurement life for long shifts
• CAT IV600V/CAT III1000V safety rating for industrial environments
• HART-capable port connections and 24V loop supply for protocol testing
• 1000V true-rms measurement capability for high-voltage testing
• 30mA maximum current with 1mA resolution for fine loop adjustments
• AA battery power with 140h typical measurement life for long shifts
• CAT IV600V/CAT III1000V safety rating for industrial environments
• HART-capable port connections and 24V loop supply for protocol testing
Applications
• Suitable for commissioning and calibrating 4–20mA control loops
• Ideal for fault-finding on plant instrumentation and transmitters
• Used with HART devices for field configuration and verification
• Can be used for multimeter diagnostics on power-distribution networks
• Used for routine calibration checks in electrical and automation workshops
• Ideal for fault-finding on plant instrumentation and transmitters
• Used with HART devices for field configuration and verification
• Can be used for multimeter diagnostics on power-distribution networks
• Used for routine calibration checks in electrical and automation workshops
What battery arrangement powers the instrument and how long does it run?
It uses four AA batteries and provides about 140 h of measurement operation under typical conditions.
What environmental range supports on-site use?
It operates between -20°C and 55°C and can be stored from -40°C to 60°C, with humidity tolerance up to 95% at 30°C.
How does it handle current sourcing into loops with external power?
It can simulate 0.000–20.000 mA with external loop supplies of 15–48V and drives up to 1000 Ω at 20 mA.
Which standards and safety classifications are met for industrial testing?
It complies with IEC 61010-1 and meets Pollution Degree 2 requirements, rated CAT IV 600V and CAT III 1000 V.
What measurement and output capabilities support frequency and AC testing?
Frequency measurement extends to 20 kHz and the true-rms voltage range reaches 1000V with specified accuracy.
Supplied with
AC175 alligator clips, AA 1.5 V alkaline batteries (x4, installed), TL71 safety-designed test lead set
Related links
- Druck Genii IS Multi-Function Calibrator 1000V ac/dc 183 mm 32 mm 87 mm
- Fluke 725 Multi-Function Calibrator 30V 236 mm 130 mm 47 mm
- Extech PRC30 Multi-Function Calibrator 20V 44 mm 159 mm 80 mm
- Time Electronics 1017 Multi-Function Calibrator 100V 119 mm 47 mm 96 mm
- RS PRO RS 135 Multi-Function Calibrator 24V 214 mm 98.7 mm 56 mm
- Druck Genii Multi-Function Calibrator 600V 42 mm 84 mm 195 mm
- Aoip Instrumentation CALYS 50 Multi-Function Calibrator 50V 50 mm 210 mm 110 mm
- Aoip Instrumentation CALYS 75 Multi-Function Calibrator 50V 50 mm 210 mm 110 mm