Dold Standstill Monitoring Relay, 1, 3 Phase, 3PDT, DIN Rail
- RS Stock No.:
- 181-2783
- Mfr. Part No.:
- LH5946.48/61 20-400mV UH=AC230V 0,2-6s
- Manufacturer:
- Dold
Subtotal (1 unit)*
HK$7,028.98
FREE delivery for orders over HK$250.00
In Stock
- 1 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | HK$7,028.98 |
*price indicative
- RS Stock No.:
- 181-2783
- Mfr. Part No.:
- LH5946.48/61 20-400mV UH=AC230V 0,2-6s
- Manufacturer:
- Dold
Specifications
Product overview and Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Dold | |
| Monitoring Application | Standstill | |
| Electrical Phase | 1, 3 | |
| Contact Configuration | 3PDT | |
| Mounting Type | DIN Rail | |
| Time Delay | 0.2 → 6s | |
| Series | LH5946 | |
| Terminal Type | Screw | |
| Dimensions | 121 x 45 x 90mm | |
| Minimum Operating Temperature | -25°C | |
| Height | 90mm | |
| Width | 45mm | |
| Maximum Operating Temperature | +60°C | |
| Operating Temperature Range | +60°C | |
| Length | 121mm | |
| Select all | ||
|---|---|---|
Brand Dold | ||
Monitoring Application Standstill | ||
Electrical Phase 1, 3 | ||
Contact Configuration 3PDT | ||
Mounting Type DIN Rail | ||
Time Delay 0.2 → 6s | ||
Series LH5946 | ||
Terminal Type Screw | ||
Dimensions 121 x 45 x 90mm | ||
Minimum Operating Temperature -25°C | ||
Height 90mm | ||
Width 45mm | ||
Maximum Operating Temperature +60°C | ||
Operating Temperature Range +60°C | ||
Length 121mm | ||
- COO (Country of Origin):
- DE
No external sensors necessary
Independent of direction
Broken wire detection
Forcibly guided safety contacts:
3 NO contacts, 1 NC contact for AC 250 V
2 semiconductor monitoring outputs
1 monitoring output (NO contact)
Adjustable voltage setting
Adjustable standstill time delay
LED indicators for standstill, event of line breakage and operation voltage
Suitable for operation with inverters
Width 45 mm
Advantages / Customer benefit
Without sensor and safe
Fast reaction time
Easy to retrofit
Combined with Interlock SAFEMASTER STS
Independent of direction
Broken wire detection
Forcibly guided safety contacts:
3 NO contacts, 1 NC contact for AC 250 V
2 semiconductor monitoring outputs
1 monitoring output (NO contact)
Adjustable voltage setting
Adjustable standstill time delay
LED indicators for standstill, event of line breakage and operation voltage
Suitable for operation with inverters
Width 45 mm
Advantages / Customer benefit
Without sensor and safe
Fast reaction time
Easy to retrofit
Combined with Interlock SAFEMASTER STS
