Schneider Electric Acti 9 iC60H MCB, 2P, 20A Curve C, 440V AC, 100 → 133V DC, 10 kA Breaking Capacity
- RS Stock No.:
- 791-3348
- Mfr. Part No.:
- A9F54220
- Manufacturer:
- Schneider Electric
Price Each**
Was HK$1,232.30
You pay
HK$511.90
26 In stock for delivery within 3 working days*
* Delivery dates may change based on your chosen quantity and delivery address.
FREE delivery for orders over HK$850.00
Units | Per unit |
---|---|
1 + | HK$511.90 |
**price indicative
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS Stock No.:
- 791-3348
- Mfr. Part No.:
- A9F54220
- Manufacturer:
- Schneider Electric
- COO (Country of Origin):
- BG
Acti9 iC60H MCBs 2 Pole
iC60H series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overload currents it also protects people against indirect contact with TN and IT neutral systems. Fully compliant with standards IEC/EN 60898 and IEC/EN 60947-2. ACTi 9 is fully tested, approved and certified by national and international third parties. It guarantees that your installation is safe and compliant with all relevant safety standards which demonstrates to your customers that you use industry-approved materials and best practices. These MCBs are normally used for high inductive loads where switching surges are high. Providing essential protection in industrial and commercial buildings, these miniature circuit breakers work especially well in polluted environments and networks.
VisiSafe guarantees the downstream circuit is always safe regardless of overvoltage conditions, even in the most demanding environments; the green strip indicates the safe position of contacts.
VisiTrip red window on the front face indicates fault tripping allowing fast diagnosis, resolution, and reclosing loads for easier building management and reduced downtime
VisiTrip red window on the front face indicates fault tripping allowing fast diagnosis, resolution, and reclosing loads for easier building management and reduced downtime
Benefits and Features
Downstream circuit is always safe
Class-2 insulation: ensures continuous protection for both operators and unqualified persons.
Insulated terminals (IP20)
Highly durable with robust connections that provide twice the standard tightening torque
Provide greater continuity of service thanks to VisiTrip
Double clip for dismounting with comb busbar in place
Class-2 insulation: ensures continuous protection for both operators and unqualified persons.
Insulated terminals (IP20)
Highly durable with robust connections that provide twice the standard tightening torque
Provide greater continuity of service thanks to VisiTrip
Double clip for dismounting with comb busbar in place
Standards
IEC 60898 - Relates to Low Voltage Circuit Breakers for use in household and similar
Installations. In the UK traditionally known as miniature circuit breakers
(MCBs).
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCBs) and also air circuit breakers (ACBs).
Installations. In the UK traditionally known as miniature circuit breakers
(MCBs).
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCBs) and also air circuit breakers (ACBs).
Q: What exactly does a miniature circuit breaker do?
A: It protects wires from overloads and short-circuits. For overload protection the temperature of a bimetal, through which the current passes is decisive. If the nominal current—the current the circuit breaker is designed for—rises slightly, the bimetal heats up to a greater extent and, after a certain period of time, this causes the switching mechanism to trip. Today MCBs are installed in all our homes, offices and other buildings, protecting the electrical wires from damage. They have the advantage that they can be manually reset without having to replace wire as in the case of the traditional fuse. The MCBs have either a button or lever that can be flicked to reset it. They are used instead of fuses due to their convenience and improved safety features.
Q: What is the differences in the Tripping Curves B, C, and D?
A: Curve B: Tripping: 3 to 5 times the rated current.
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Applications: protection of high surge circuits, welders, transformers and motors
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Applications: protection of high surge circuits, welders, transformers and motors
Schneider Electric MCB, 20A Rated Current, 500V AC Rated Insulation Voltage - Acti9 Series - A9F54220
Get the upper hand over electrical faults with this MCB from Schneider Electric. It's a reliable powerhouse that does double duty by providing protection from both short circuits and overload currents. This cuts out the risk of equipment being damaged or personnel coming to harm. The unit's thermoplastic housing shrugs off impacts and scratches, making it a reliable performer in harsh environments. What's more, it has compact dimensions of 85 (H) x 36 (W) x 78.5mm (D), so it fits into an enclosure where space is at a premium.
Features & Benefits
• Breaking capacity of 10kA at 440V AC to handle sudden current spikes without suffering damage
• DIN-rail mounting is simple and tool-free, saving time and effort
• IP20 rating shows that it's protected from objects larger than 12mm in size
• Electrical durability of 10,000 operating cycles for long-term performance
• DIN-rail mounting is simple and tool-free, saving time and effort
• IP20 rating shows that it's protected from objects larger than 12mm in size
• Electrical durability of 10,000 operating cycles for long-term performance
Applications
• Automotive plants
• Transportation industry
• Transportation industry
How do I reset this MCB after it has tripped?
You can immediately reactivate this breaker using the front toggle switch. Before resetting it, it's important to check that the fault has been cleared to prevent damage to your equipment.
Merlin Gerin – MCBs
Miniature Circuit Breakers; Contact Position indicated by switch levers
Attribute | Value |
---|---|
Number of Poles | 2P |
Current Rating | 20A |
Tripping Characteristics | Type C |
Rated AC Voltage | 440 V, 12 → 133 V, 220 → 240 V, 380 → 415V |
Rated DC Voltage | 100 → 133V |
Breaking Capacity at Maximum Voltage Rating | 10 kA |
Range | Acti 9 |
Series | iC60H |
Circuit Breaker Type | MCB |
Length | 85mm |
Width | 36mm |
Mounting Style | DIN Rail Mount |
Depth | 78.5mm |
Better World Verification | Green Premium |
Better World Product | Yes |
Tripping Mechanism | Thermal-Magnetic |
Terminal Contact Type | Screw |
Reset Actuator Type | Rocker Switch |