ABB System Pro M Compact S303 Miniature Circuit Breaker, 3-Pole, 20A, Type B, 415V ac AC, 125 V dc DC, 100 kA Breaking
- RS Stock No.:
- 200-315
- Mfr. Part No.:
- 2CDS383001R0205
- Manufacturer:
- ABB
Subtotal (1 unit)*
HK$2,907.10
FREE delivery for orders over HK$250.00
Stocked by manufacturer
- Ready to ship from 04 January 2027
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | HK$2,907.10 |
*price indicative
- RS Stock No.:
- 200-315
- Mfr. Part No.:
- 2CDS383001R0205
- Manufacturer:
- ABB
Specifications
Product overview and Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Product Type | Miniature Circuit Breaker | |
| Number of Poles | 3 | |
| Current Rating | 20A | |
| Tripping Characteristics | Type B | |
| Rated AC Voltage | 415V ac | |
| Rated DC Voltage | 125V dc | |
| Breaking Capacity | 100kA | |
| Mount Type | DIN Rail | |
| Range | System Pro M Compact | |
| Series | S303 | |
| Terminal Type | Screw | |
| IP Rating | IP20, IP40 | |
| Width | 17.5mm | |
| Standards/Approvals | IEC/EN 60947-2 IEC/EN 60898-1 UL 1077 CSA 22.2. No.235 GB/T 14048.2 GB/T 10963.1 | |
| Height | 88mm | |
| Depth | 69mm | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Product Type Miniature Circuit Breaker | ||
Number of Poles 3 | ||
Current Rating 20A | ||
Tripping Characteristics Type B | ||
Rated AC Voltage 415V ac | ||
Rated DC Voltage 125V dc | ||
Breaking Capacity 100kA | ||
Mount Type DIN Rail | ||
Range System Pro M Compact | ||
Series S303 | ||
Terminal Type Screw | ||
IP Rating IP20, IP40 | ||
Width 17.5mm | ||
Standards/Approvals IEC/EN 60947-2 IEC/EN 60898-1 UL 1077 CSA 22.2. No.235 GB/T 14048.2 GB/T 10963.1 | ||
Height 88mm | ||
Depth 69mm | ||
- COO (Country of Origin):
- DE
ABB S300P Series Miniature Circuit Breaker, 20A Current, 3 Poles - 2CDS383001R0205
This miniature circuit breaker provides overcurrent protection for three-phase circuits in commercial and industrial installations. It is designed for DIN-rail mounting and operated via a toggle reset, offering straightforward manual control. The device accommodates both AC and DC systems, allowing use where mixed-voltage protection is required.
Features and Benefits:
• 25kA breaking capacity limits fault energy and reduces equipment damage
• Type B tripping characteristic MCB protects against low-level fault currents
• 125V DC rated MCB 3 pole permits use in DC power circuits
• 415V AC 20A circuit breaker screw Terminal supports typical industrial supplies
• IP20/IP40 miniature circuit breaker offers Basic ingress protection levels
• Type B tripping characteristic MCB protects against low-level fault currents
• 125V DC rated MCB 3 pole permits use in DC power circuits
• 415V AC 20A circuit breaker screw Terminal supports typical industrial supplies
• IP20/IP40 miniature circuit breaker offers Basic ingress protection levels
Applications
• Suitable for distribution boards in light-commercial premises
• Ideal for protecting small motor circuits and lighting runs
• Used with DIN-rail enclosures in plant control cabinets
• Can be used for DC control circuits requiring 125V protection
• Suitable for replacement of three-pole protection devices in panels
• Ideal for protecting small motor circuits and lighting runs
• Used with DIN-rail enclosures in plant control cabinets
• Can be used for DC control circuits requiring 125V protection
• Suitable for replacement of three-pole protection devices in panels
What Terminal connection method is provided for installation?
Screw terminals are supplied to secure conductors and facilitate wiring.
How is the device mounted within electrical panels?
It is intended for DIN-rail mounting to integrate with standard distribution assemblies.
Which tripping behaviour does it offer for sensitive circuits?
It employs a Type B characteristic which trips on relatively low fault currents.
What manual control is available for resetting after a trip?
A toggle reset actuator is provided for manual reclosure of the circuit.
Which standards apply to its construction and testing?
It meets multiple international standards including IEC/EN 60947-2 and IEC/EN 60898-1.
Related links
- ABB System Pro M Compact S303 Miniature Circuit Breaker 20A 415V ac AC 25 kA Breaking
- ABB System Pro M Compact S303 Miniature Circuit Breaker 20A 415V ac AC 25 kA Breaking
- ABB System Pro M Compact S303 Miniature Circuit Breaker 20A 415V ac AC 25 kA Breaking
- ABB System Pro M Compact S303 Miniature Circuit Breaker 6A 415V ac AC 25 kA Breaking
- ABB System Pro M Compact S303 Miniature Circuit Breaker 10A 415V ac AC 25 kA Breaking
- ABB System Pro M Compact S303 Miniature Circuit Breaker 63A 415V ac AC 25 kA Breaking
- ABB System Pro M Compact S303 Miniature Circuit Breaker 40A 415V ac AC 25 kA Breaking
- ABB System Pro M Compact S303 Miniature Circuit Breaker 50A 415V ac AC 25 kA Breaking