Honeywell GLB Series Rod Limit Switch, 1 NO/1 NC, IP67, Die Cast Zinc Housing, 600V ac, 10A
- RS Stock No.:
- 207-1997
- Mfr. Part No.:
- GLBC02A2B
- Manufacturer:
- Honeywell
Bulk discount available
Subtotal (1 unit)*
HK$2,506.00
Stock information currently inaccessible - Please check back later
Units | Per unit |
|---|---|
| 1 - 4 | HK$2,506.00 |
| 5 + | HK$2,430.80 |
*price indicative
- RS Stock No.:
- 207-1997
- Mfr. Part No.:
- GLBC02A2B
- Manufacturer:
- Honeywell
Specifications
Product overview and Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Honeywell | |
| Actuator Type | Rod | |
| Product Type | Limit Switch | |
| Contact Configuration | 1 NO/1 NC | |
| IP Rating | IP67 | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Switching Current | 10A | |
| Terminal Type | M20 | |
| Series | GLB | |
| Minimum Operating Temperature | -25°C | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 600V ac | |
| Maximum Operating Temperature | 85°C | |
| Width | 42mm | |
| Standards/Approvals | CCC, CE, CSA, UL | |
| Depth | 55.9mm | |
| Length | 145.8mm | |
| Hazardous Area Certification | NO | |
| Operating Force | 0.33Nm | |
| Mechanical Life | 15000000Operations | |
| Conduit Entry | 20 mm | |
| Mounting Orientation | Standard | |
| Select all | ||
|---|---|---|
Brand Honeywell | ||
Actuator Type Rod | ||
Product Type Limit Switch | ||
Contact Configuration 1 NO/1 NC | ||
IP Rating IP67 | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Switching Current 10A | ||
Terminal Type M20 | ||
Series GLB | ||
Minimum Operating Temperature -25°C | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 600V ac | ||
Maximum Operating Temperature 85°C | ||
Width 42mm | ||
Standards/Approvals CCC, CE, CSA, UL | ||
Depth 55.9mm | ||
Length 145.8mm | ||
Hazardous Area Certification NO | ||
Operating Force 0.33Nm | ||
Mechanical Life 15000000Operations | ||
Conduit Entry 20 mm | ||
Mounting Orientation Standard | ||
- COO (Country of Origin):
- GB


Honeywell GLB Series Limit Switch, 20mm Conduit Entry, 1 NO/1 NC Contact Configuration - GLBC02A2B
This limit switch provides position detection for industrial automation and control systems, offering a rugged control input for mechanical processes. It is designed for straightforward installation in demanding environments where a rod-type actuator is required, delivering snap-action electrical signalling for machine control and safety interlocks.
Features and Benefits:
• Electrostatic epoxy-coated zinc housing for corrosion resistance and longevity
• 1 NO 1 NC snap-action contacts rated for 600V and 10 A for heavy-duty switching
• IP67 ingress protection enabling use in wet and dusty conditions
• Mechanical life of 15,000,000 operations for sustained cycling applications
• Operating temperature range −25 to 85 °C for wide environmental tolerance
• Low operating torque of 0.33 N·m for reduced actuation force requirements
• 1 NO 1 NC snap-action contacts rated for 600V and 10 A for heavy-duty switching
• IP67 ingress protection enabling use in wet and dusty conditions
• Mechanical life of 15,000,000 operations for sustained cycling applications
• Operating temperature range −25 to 85 °C for wide environmental tolerance
• Low operating torque of 0.33 N·m for reduced actuation force requirements
Applications
• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for plunger- or cam-actuated machine safety interlocks
• Used with packaging equipment for repetitive position sensing
• Can be used for valve position feedback in process plants
• Used for indexing control on automated assembly machinery
• Ideal for plunger- or cam-actuated machine safety interlocks
• Used with packaging equipment for repetitive position sensing
• Can be used for valve position feedback in process plants
• Used for indexing control on automated assembly machinery
What conduit size does it accept for cable entry?
The enclosure accommodates an M20 conduit entry to suit standard industrial trunking.
How does the actuator type affect mounting choices?
The rod actuator provides linear contact with moving parts and permits side or end actuation in standard mounting orientations.
What materials constitute the enclosure to withstand industrial wear?
The body is MADE from zinc with an electrostatic epoxy coating to reduce corrosion and surface wear.
Which electrical standards does it comply with for safety and interoperability?
It is approved to CE, UL, CSA and CCC standards for international installation requirements.
Approvals
UL/ UL listed for Canada
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and control gear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLB limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and control gear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLB limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
Related links
- Honeywell GLB Series Rod Limit Switch IP67 600 V ac, 10 A
- Honeywell GLB Series Roller Lever Limit Switch IP67 600 V ac, 10 A
- Honeywell GLB Series Plunger Limit Switch IP67 600 V ac, 10 A
- Honeywell GLB Series Roller Lever Limit Switch IP67 600 V ac, 10 A
- Honeywell GLB Series Coil Spring Limit Switch IP67 Die Cast Zinc Housing 10A Max
- Honeywell GLA Series Rod Limit Switch IP67 600 V ac, 6 A
- RS PRO SN4107 Series Rod Limit Switch IP67, Die Cast Zinc Housing
- Honeywell GLA Series Roller Lever Limit Switch IP67 600 V ac