Data Loggers

A data logger is a compact, battery powered device equipped with an internal microprocessor, data storage and one or more sensors. They can be deployed in a variety of environments to record measurements at set intervals. The devices automatically monitor and record environmental parameters over time, allowing conditions to be measured, documented, analysed and validated. The data logger contains a sensor to receive the information and a computer chip to store it. Then the information stored in the data logger is transferred to a computer for analysis.

Depending on the particular data logger, measurements can include air temperature, relative humidity, AC/DC current and voltage, differential pressure, time-of-use (lights, motors, etc.), light intensity, water temperature, water level, dissolved oxygen, soil moisture, rainfall, wind speed and direction, leaf wetness, pulse signals, room occupancy, plug load, and many more.
Why would you use a data logger?

Data logging is the collection of data over a period of time, and is something often used in scientific experiments. Data logging systems typically monitor a process using sensors linked to a computer. Most data logging can be done automatically under computer control.

Sensors have an important role in the data logging process. All physical properties can be measured with sensors such as light, heat, sound, pressure, acidity and humidity.
The sensors send signals to an interface box, which is linked to a computer. The interface box converts analogue signals to digital signals that the computer can understand.
The computer controlling the process will take readings at regular intervals. The time interval for data logging is the time between readings. The logging period is the total length of time over which readings are taken.
The readings are stored in tables and can be displayed in graphs or passed to an application for analysis.
Sometimes it is necessary to record data 'out in the field'. This is called remote data logging. Readings are stored and brought back to a computer where they are downloaded and analysed. The equipment in these situations needs to be very robust. For example equipment used to monitor water levels would have to be waterproof and equipment working in a satellite would have to be able to withstand vibration during launch and recovery.

How do you use a Data Logger?
● Download and install software on mobile device or laptop
● Connect to data logger and launch parameters
● Place in location and record data for desired period of time
● Reconnect to data logger via mobile device or laptop
● Download data file and readout with analysis software

...
Read more Read less

Filters

Viewing 1 - 20 of 169 products
Results per page
Description Price Measurement Parameters Number of Input Channels Sensor Type Interface Type Maximum Temperature Measurement Maximum Voltage Measurement Best Temperature Measurement Accuracy Temperature Measurement Resolution Power Source Maximum Humidity Measurement IP Rating Minimum Operating Temperature Maximum Operating Temperature Best Humidity Measurement Accuracy
RS Stock No. 490-1064
Mfr. Part No.EL-USB-2
BrandLascar
HK$882.40
Each
units
Dew Point, Humidity, Temperature - - USB +80 °C - ± 0.55 °C 0.5°C Battery 100%RH IP67 -35°C +80°C ± 2.25 %RH
RS Stock No. 466-6115
Mfr. Part No.EL-USB-1
BrandLascar
HK$480.95
Each
units
Temperature - Temperature USB +80 °C - ± 0.5 °C 0.5 °C, 1 °F Battery - IP67 -35°C +80°C -
RS Stock No. 500-711
Mfr. Part No.EL-USB-2-LCD
BrandLascar
HK$950.74
Each
units
Dew Point, Humidity, Temperature - Dew Point, Humidity, Temperature USB +80 °C - ± 0.55 °C 0.5 °C, 1 °F Battery 100%RH IP67 -35°C +80°C ± 2.25 %RH
RS Stock No. 492-5105
Mfr. Part No.TC-08
HK$4,099.17
Each
units
Temperature 8 B, E, J, K, N, R, S, T USB +400 (T) °C, +910 (E) °C, +1200 (J) °C, +1300 (N) °C, +1370 (K) °C, +1760 (S) °C, +1820 (B) °C - ±0.2 % 0.025°C Mains - - - - -
RS Stock No. 712-5471
Mfr. Part No.0572 0566
BrandTesto
HK$1,388.83
Each
units
Humidity, Temperature 2 Capacitive, NTC USB +70 °C - ±0.5 °C 0.1°C Battery 100%RH IP20 -20°C +70°C ±0.03 %RH
RS Stock No. 732-0578
Mfr. Part No.0572 1754
BrandTesto
HK$2,505.36
Each
units
Humidity, Temperature 2 Capacitive, NTC USB +50 (TD) °C - ±0.4 °C 0.1°C Battery 100%RH IP54 -20°C +55°C ±0.03 %RH
RS Stock No. 734-9731
Mfr. Part No.EL-USB-2-LCD+
BrandLascar
HK$950.74
Each
units
Dew Point, Humidity, Temperature - Dew Point, Humidity, Temperature USB +80 °C - ± 0.45 °C 0.5 °C, 1 °F Battery 100%RH IP67 -35°C +80°C ± 2.05 %RH
RS Stock No. 910-7065
Mfr. Part No.EL-BT-2
BrandLascar
HK$1,492.77
Each
units
Humidity, Temperature - Humidity Micro USB +60 °C - ±0.4 °C 0.1°C Battery 100%RH IP55 -20°C +60°C ±2 %RH
RS Stock No. 775-1070
Mfr. Part No.EL-GFX-2
BrandLascar
HK$1,598.18
Each
units
Humidity, Temperature 1 - USB +80 °C, +176 °F - ± 0.35 °C 0.1 °C, 0.1 °F Battery 100%RH IP67 -30°C +80°C ± 2.05 %RH
RS Stock No. 666-8179
Mfr. Part No.EL-USB-1-PRO
BrandLascar
HK$1,253.03
Each
units
Temperature - - USB +125 °C - ± 0.2 °C 0.1 °C, 0.1 °F Battery - IP67 -40°C +125°C -
RS Stock No. 756-7339
Mfr. Part No.WIFI-TP
BrandCorintech
HK$1,746.99
Each
units
Temperature 1 External Thermistor USB / WiFi +125 °C - ± 0.6 0.1°C Battery - IP43 -20°C +60°C -
RS Stock No. 756-7336
Mfr. Part No.WIFI-TH
BrandCorintech
HK$1,897.25
Each
units
Temperature 2 Internal Temperature/Humidity USB / WiFi +60 °C - ± 0.3 0.1°C Battery 100 IP55 -20°C +60°C ± 1.8
RS Stock No. 734-9740
Mfr. Part No.EL-USB-1-LCD
BrandLascar
HK$632.78
Each
units
Temperature - - USB +80 °C - ± 0.5 °C 0.5°C Battery - IP67 -20°C +80°C -
RS Stock No. 656-0924
Mfr. Part No.TK-4023-PK-RS
BrandGemini
HK$936.98
Each
units
Temperature 1 NTC Serial, USB +125 °C - ±0.4 °C 0.05°C Battery - IP30 -40°C +85°C -
RS Stock No. 536-3277
Mfr. Part No.EL-USB-4
BrandLascar
HK$569.98
Each
units
Current - - USB - - - - Battery - - -35°C +80°C -
RS Stock No. 666-8166
Mfr. Part No.EL-USB-2+
BrandLascar
HK$795.45
Each
units
Dew Point, Humidity, Temperature - - USB +80 °C - ± 0.45 °C 0.5 °C, 1 °F Battery 100%RH IP67 -35°C +80°C ± 2.05 %RH
RS Stock No. 786-5071
Mfr. Part No.WIFI-TH+
BrandCorintech
HK$2,274.04
Each
units
Humidity, Temperature 2 Internal Temperature/Humidity USB / WiFi +60 °C - ± 0.2 0.01°C Battery 100%RH IP55 -20°C +60°C ±1.8 %
RS Stock No. 111-6765
Mfr. Part No.P01157160
HK$23,123.79
Each
units
Current, Energy, Frequency, Harmonics, Power, Voltage 4, 5 Current Sensor Bluetooth, Ethernet, USB, Wi-Fi - 600 V ac @ 400 Hz, 1000 V ac @ 50/60 Hz, 1000 V dc - - From Unit Under Test, Mains - IP67 -20°C +50°C -
RS Stock No. 775-1073
Mfr. Part No.EL-GFX-DTC
BrandLascar
HK$1,462.30
Each
units
Temperature 2 J, K, T USB +390 °C, +734 °F, +1190 °C, +1350 °C, +2174 °F, +2462 °F - ±0.5 °C, ±0.9 °F 0.1 °C, 0.1 °F Battery - - -10°C +40°C -
RS Stock No. 126-723
Mfr. Part No.EL-USB-RT
BrandLascar
HK$510.01
Each
units
Dew Point, Humidity, Temperature - - USB +60 °C - ±1.5 °C 0.3 °C, 0.6 °F Mains 100%RH - -10°C +60°C ±4.5 %RH
Related Products
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam ...
Description:
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam and pump linkage for long lifePumping handle included on all modelsSafety relief valve to prevent overloadAutomatic by-pass port to prevent over-extensionWiper seal for extended lifeThick base material with large area for increased ...
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam ...
Description:
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam and pump linkage for long lifePumping handle included on all modelsSafety relief valve to prevent overloadAutomatic by-pass port to prevent over-extensionWiper seal for extended lifeThick base material with large area for increased ...
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam ...
Description:
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam and pump linkage for long lifePumping handle included on all modelsSafety relief valve to prevent overloadAutomatic by-pass port to prevent over-extensionWiper seal for extended lifeThick base material with large area for increased ...
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam ...
Description:
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam and pump linkage for long lifePumping handle included on all modelsSafety relief valve to prevent overloadAutomatic by-pass port to prevent over-extensionWiper seal for extended lifeThick base material with large area for increased ...