Product overview and Technical data sheets
Legislation and Compliance
- COO (Country of Origin):
- FR
Product Details
PNOZ X10, Dual Channel
Introducing the PNOZ X10 range of safety relay from the well-known brand PILZ, manufacturer of many safety related monitoring products. The PNOZ X10 range is the top of its class offering you different modes of operation including, single, automatic and dual channel functions. You will find that the PNOZ X10 has many different applications that you can use that offer you versatility in the face of machine safety.
Features and benefits
LED indicator statuses to support switching channel status between 1 or 2 signals & also for monitoring the supply voltage currently in the relay
Featuring 6 safety contacts (instantaneous) and 4 auxiliary contacts furthering the reliability of the machines safety output.
DIN rail mounting as standard
Single/Dual channel operation
Detection of short circuits across the contacts which can specifically detect earth faults and short circuiting.
Featuring 6 safety contacts (instantaneous) and 4 auxiliary contacts furthering the reliability of the machines safety output.
DIN rail mounting as standard
Single/Dual channel operation
Detection of short circuits across the contacts which can specifically detect earth faults and short circuiting.
Safety features
The circuit is redundant with built in self-monitoring
Safety functions remain effective in the case of a component failure
Correct opening and closing of the safety functions is tested automatically at the end of each of the relays on/off safety cycles.
Your X10 is short circuit proof, using an electronic fuse on a DC supply provides this reliability.
Safety functions remain effective in the case of a component failure
Correct opening and closing of the safety functions is tested automatically at the end of each of the relays on/off safety cycles.
Your X10 is short circuit proof, using an electronic fuse on a DC supply provides this reliability.
Applications
Emergency stop buttons
Safety gate limit switches
Reset buttons
Light barriers
Technical safety parameters
EN 60947-5-1
EN 60204-1
VDE 0113-1
EN 60204-1
VDE 0113-1
Specifications
Attribute | Value |
---|---|
Supply Voltage | 24V dc |
Number of Channels | 1, 2 |
Safety Contacts | 6 |
Function | Safety Switch/Interlock |
Auxiliary Contacts | 4 |
Range | PNOZ X |
Safety Category ISO 13849-1 | 3 |
PL ISO 13849-1 | e |
SIL IEC 61508 | 3 |
Terminal Type | Screw |
Width | 90mm |
Depth | 121mm |
Series | PNOZ X10 |
Length | 87mm |
Performance Level | e |