Schneider Electric Dual-Channel Emergency Stop, Safety Mat/Edge, Safety Switch/Interlock Safety Relay, 230V ac, 2
- RS Stock No.:
- 464-495
- Mfr. Part No.:
- XPSATE3710P
- Manufacturer:
- Schneider Electric
Discontinued product
Alternative
This product is not currently available. Here is our alternative recommendation.
- RS Stock No.:
- 464-495
- Mfr. Part No.:
- XPSATE3710P
- Manufacturer:
- Schneider Electric
Legislation and Compliance
- COO (Country of Origin):
- ID
Product Details
XPS ATE, Dual Channel with Timed Delay (0-30s)
The Schneider Electric XPS-ATE range of safety modules have been created and designed to be used for monitoring emergency stop circuits. They provide protection for both machines and operators through immediately stopping the dangerous movement on receipt of a stop instruction or if a fault is detected within the circuit.
Features & Benefits
2 N/O instantaneous outputs provide stop category 0, 3 N/O timed contacts provide stop category 1 by allowing controlled deceleration of the motor until a complete stop is achieved
4 solid state outputs for PLC signalling
Monitored start button feature
Delay time: 0 – 30 s. adjustable in 12 steps by using the selector switch in the module front cover
Provides protection for machine and operator by immediately stopping dangerous movement on receipt of a stop instruction from operator, or on detection of a fault in the safety circuit. Applications include safety mats, safety edges, e-stop and safety gates
2 channel monitoring and feedback loop
Shorts across contacts, between channels and ground monitored
Voltage on input channels: 48Vdc
4 LEDs to indicate control supply/fuse, input channel A and B, stop Cat. 1 outputs closed
Internal electronic fuse for input channels reset on removal of fault
Synchronisation time between input A and B when using automatic start feature = 75ms approx
Pull off terminals for a simple and quick maintenance
4 solid state outputs for PLC signalling
Monitored start button feature
Delay time: 0 – 30 s. adjustable in 12 steps by using the selector switch in the module front cover
Provides protection for machine and operator by immediately stopping dangerous movement on receipt of a stop instruction from operator, or on detection of a fault in the safety circuit. Applications include safety mats, safety edges, e-stop and safety gates
2 channel monitoring and feedback loop
Shorts across contacts, between channels and ground monitored
Voltage on input channels: 48Vdc
4 LEDs to indicate control supply/fuse, input channel A and B, stop Cat. 1 outputs closed
Internal electronic fuse for input channels reset on removal of fault
Synchronisation time between input A and B when using automatic start feature = 75ms approx
Pull off terminals for a simple and quick maintenance
XPSATE3710P Schneider Electric Preventa Safety Relay Module.
- Preventa safety module XPSATE.
- For emergency stop and switch monitoring.
- Configurable
- Captive screw clamp terminals.
- 2 NO (volt free) instant opening, 3 NO (volt free) relay time delay opening.
- 3 solid state additional circuits.
- Rated Supply voltage 230 V ac.
- Frequency 50 to 60 Hz.
- Control circuit voltage 48 V dc.
- Maximum power consumption (VA) 3.3 VA.
- Breaking 1 A at 24 V (DC-13).
- Minimum output current 10 MA (relay output).
- Minimum output voltage 17 V (relay output).
- Response time 20 Ms (input open).
- 4 LEDs.
- Mounting 35 mm DIN rail.
- Net weight 0.38 Kg.
Protection.
- IP20 (terminals) conforming to EN/IEC 60529.
- IP40 (enclosure) conforming to EN/IEC 60529.
Safety Levels.
- Can reach PL d/category 3 time delay safety outputs conforming to EN/ISO 13849-1, Can reach PL e/category 4 instantaneous safety outputs conforming to EN/ISO 13849-1, Can reach SILCL 3 instantaneous safety outputs conforming to EN/IEC 62061, Can reach SILCL 2 time delay safety outputs conforming to EN/IEC 6206.
Standards
EN/IEC 60204-1, EN/ISO 13850, EN/IEC 60947-5-1, CSA, UL, TÜV.
Specifications
Attribute | Value |
---|---|
Supply Voltage | 230V ac |
Number of Channels | 2 |
Safety Contacts | 2 |
Function | Emergency Stop, Safety Mat/Edge, Safety Switch/Interlock |
Auxiliary Contacts | 4 |
Reset Method | Automatic & Manual |
Range | Preventa |
Safety Category ISO 13849-1 | 3 |
Terminal Type | Screw |
Configurable | Yes |
Series | XPS ATE |
Width | 45mm |
Depth | 114mm |
Length | 99mm |