Eaton DLIMS Series Safety Contactors
The DILMS series of safety contactors from Eaton offer reliable switching in safety-related device applications.
As standard, all versions of the DILMS safety contactor are equipped with a top-mounted auxiliary contact, to stop tampering and prevent manual actuation this is non-detachable. For added safety, this contactor has integrated mirror contacts and interlocking opposite contacts.
With a built-in inspection window placed immediately above the switch position indicator, it's easy to monitor the operating status of your control systems at all times. This contactor has a yellow cover to allow for fast and efficient identification of your safety devices. The dependable design of this contactor provides the perfect solution for the protection of your devices from manual activation.
Available in four sizes the DILMS range of contactors cover a power range between 7 and 150 A. This series also features the DILAS safety relays which are available in three different coil voltages to complete your safety system.
As standard, all versions of the DILMS safety contactor are equipped with a top-mounted auxiliary contact, to stop tampering and prevent manual actuation this is non-detachable. For added safety, this contactor has integrated mirror contacts and interlocking opposite contacts.
With a built-in inspection window placed immediately above the switch position indicator, it's easy to monitor the operating status of your control systems at all times. This contactor has a yellow cover to allow for fast and efficient identification of your safety devices. The dependable design of this contactor provides the perfect solution for the protection of your devices from manual activation.
Available in four sizes the DILMS range of contactors cover a power range between 7 and 150 A. This series also features the DILAS safety relays which are available in three different coil voltages to complete your safety system.
Features and Benefits
Safe status monitoring of the contactor (inspection window) manual activation is not possible
Eligible to be used for Emergency-stop application with controlled start (category 4)
Reliable and self-monitoring machine-control circuits
Interlocking opposing contacts
Mirror contacts
Highlighted in yellow (RAL1004)
Reliable screw terminals
Top-mounted and non-detachable auxiliary contact (at the front)
Eligible to be used for Emergency-stop application with controlled start (category 4)
Reliable and self-monitoring machine-control circuits
Interlocking opposing contacts
Mirror contacts
Highlighted in yellow (RAL1004)
Reliable screw terminals
Top-mounted and non-detachable auxiliary contact (at the front)
Typical Applications
Contactors can be used across a multitude of applications, users will commonly find these contactors being used within industrial settings such as factory automation and control, railway transportation, electrical systems, electric motor, lighting, and mechanical engineering and are a key component when safety functions and the protection of equipment and users are a requirement.
Is a Safety Contactor or Safety Relay required?
When deciding whether to use a contactor or a relay for a safety circuit there are some general rules to help make the decision easier. A contactor should be used when the current is 9A or more, up to 1000 V ac and can be used for 1 or 3 phase safety applications. A relay should be used when the current is 10A or less, up to 250 V ac and usually on single-phase safety applications.
Eaton DILMS Series Contactor, 24 to 27V DC Coil Voltage, 3NO Normal State Configuration - 191711 DILMS25-23(RDC24)
This safety contactor is essential for ensuring safe operation in industrial motor control and protection applications. It efficiently manages significant electrical loads, making it a vital component for automation and mechanical systems.
Features & Benefits
• Configured with 3 poles to accommodate various circuit needs
• Supports a contact current rating of 25A
• Includes 5 auxiliary contacts for added functionality
• Equipped with screw terminals for easy installation
• Rated for loads up to 400V AC, ensuring wide applicability
• Supports a contact current rating of 25A
• Includes 5 auxiliary contacts for added functionality
• Equipped with screw terminals for easy installation
• Rated for loads up to 400V AC, ensuring wide applicability
Applications
• Used for starting and stopping various motor types
• Employed in automation systems requiring precise control
• Suitable for managing non-inductive and slightly inductive loads
• Valuable in requiring safety mechanisms to prevent faults
• Employed in automation systems requiring precise control
• Suitable for managing non-inductive and slightly inductive loads
• Valuable in requiring safety mechanisms to prevent faults
What is the maximum ambient temperature this device can operate under?
It can operate in environments with temperatures up to +60°C.
How many auxiliary contacts does it feature, and what is their configuration?
It includes 5 auxiliary contacts, comprising 2 normally open and 3 normally closed.
What type of installation does the device require?
It features screw terminals, facilitating straightforward and secure installation.
Is it suitable for high-efficiency motors?
Yes, it is compatible with motors that meet efficiency class IE3 requirements.
Note
Eaton formerly known as Moeller
Attribute | Value |
---|---|
Coil Voltage | 24 → 27 V dc |
Number of Poles | 3 |
Contact Voltage Rating | 400 V ac |
Contact Current Rating | 25 A |
Series | DILMS |
Function | Safety |
Normal State Configuration | 2N/O |
Auxiliary Contact Configuration | 2NO + 3NC |
Number Of Auxiliary Contacts | 5 |
Terminal Type | Screw |
Width | 45mm |
Length | 138mm |
Depth | 138mm |
Control Voltage | 24 V dc |
Pole and Throw Configuration | 3P |
Maximum Operating Temperature | +60°C |
Minimum Operating Temperature | -25°C |