Emergency stop module with time delay for SK4, BH5928

Safety category 4 in accordance with DIN EN 954
Output: 2 N/O, 1 N/C as immediate contacts and 3 off-delay N/O contacts
1 or 2-channel configuration
Line termination detection on the ON button
Optional activation via the ON button or automatic ON function when the operating voltage is met
Programmable: With / without cross-fault detection in the emergency stop-control loop
LED indicators for network, channel 1//2 and time delay
With removable terminal clamps
Internal fusing with PTC and VDR
Overall width 45 mm

Standards

EN 60204-1 (stop functions), EN 418, prEN574, prEN 954-1

Warning

  • With its gold-plated contacts the BG 5928 is also suitable for switching low voltages 1 mVA → 7 VA, 1 mW → 7 W in the 0.1 → 60 V, 1 → 300 mA range.
    The contacts also allow the max. switching current. As the gold finish would be burnt off at this current rating, the device would no longer be suitable for switching low voltages.
Specifications
Attribute Value
Supply Voltage 24 V ac/dc
Number of Channels 1, 2
Function Emergency Stop
Safety Contacts 3
Range Safemaster
Depth 118mm
Length 84mm
Width 45mm
6 Within 3 working day(s) (Global stock)
11 Within 4 working day(s) (Global stock)
Price Each
HK$ 3,301.70
(exc. GST)
units
Per unit
1 +
HK$3,301.70
Related Products
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz ...
Description:
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range ...
Chassis mounting low voltage mains transformers with a ...
Description:
Chassis mounting low voltage mains transformers with a single 230Va.c. 50/60Hz primary winding. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Double section bobbin constructionFully ...
Twin 115Va.c. 50/60Hz primary windings which may be ...
Description:
Twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operationFully shrouded bobbins100% electrical and flash testedTested in accordance with BS3535 and EN 60 742.
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their ...