Murata 3A Single Output Regulated Non-Isolated DC-DC Converter - OKR Series

Non-isolated (PoL) module
Wide input voltage range
Up to 3A output current
Adjustable output voltage via external resistors
Output ON/OFF inhibit
Output voltage sense
Over temperature and over current protection
SIP through hole package

Specifications
Attribute Value
Input Voltage Range 4.5 → 14 V dc
Input Voltage Nominal 12 V dc
Output Voltage 0.591 → 6V dc
Output Current 3A
Power Rating 15W
Mounting Type Through Hole
Number of Outputs 1
Length 10.4mm
Width 5.6mm
Depth 16.5mm
Package SIP
Minimum Temperature -40°C
Maximum Temperature +85°C
108 In stock for delivery within 3 working days
Price Each
HK$ 70.88
(exc. GST)
units
Per unit
1 - 4
HK$70.88
5 - 9
HK$67.71
10 - 24
HK$65.30
25 - 49
HK$63.15
50 +
HK$61.55
Packaging Options:
Related Products
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam ...
Description:
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam and pump linkage for long lifePumping handle included on all modelsSafety relief valve to prevent overloadAutomatic by-pass port to prevent over-extensionWiper seal for extended lifeThick base material with large area for increased ...
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam ...
Description:
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam and pump linkage for long lifePumping handle included on all modelsSafety relief valve to prevent overloadAutomatic by-pass port to prevent over-extensionWiper seal for extended lifeThick base material with large area for increased ...
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam ...
Description:
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam and pump linkage for long lifePumping handle included on all modelsSafety relief valve to prevent overloadAutomatic by-pass port to prevent over-extensionWiper seal for extended lifeThick base material with large area for increased ...
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam ...
Description:
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam and pump linkage for long lifePumping handle included on all modelsSafety relief valve to prevent overloadAutomatic by-pass port to prevent over-extensionWiper seal for extended lifeThick base material with large area for increased ...