LED Emergency Lighting Twin Spot 2 x 3 W

Product overview and Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
Product Details

Knightsbridge LED Emergency Non Maintained Twin Spot

The Knightsbridge EMTWIN65 is an IP65 rated, twin spot LED emergency light, suitable for non-maintained internal or external use. This emergency light features 2 x 3W LED and a 9.6V 2200mAh Ni-cad battery for a 3 hours emergency duration. The twin spot light is made of moulded polycarbonate.

White finish
2 x 3W non replaceable LED
450 lumens
3 hours discharge duration
IP65 rated
Powder coated pressed steel chassis
Self-extinguishing polycarbonate body and spot lights
Direct fixing, screws provided

Standards

EN55015, EN61547, EN61000-3-2, EN61347-2-7, EN61347-2-3, BSEN60598

Knightsbridge LED Emergency Lighting Twin Spot Non-Maintained

The Knightsbridge LED emergency lighting bulkhead is a 2 x 3W, non-maintained, twin spot, white LED light. The twin spotlight is made of moulded polycarbonate. This non-maintained, luminaire is only illuminated on a failure of the mains supply. This LED light is a 9.6V, 2200mAh, Ni-cad battery, for a 3 hours emergency duration.

Features and Benefits


Fitting type is twin spot
• 2 x 3W non-replaceable LED
• 450 lumens

• Voltage rating is 230V
• Discharge duration is 3hrs
• Powder-coated pressed steel Chassis
• Self-extinguishing polycarbonate Body
• Self-extinguishing polycarbonate Diffuser
• Operating temperature range is between -10℃ and 30℃

Applications


Emergency exits
• Switch rooms
• Storage areas

Certifications


EN 55015
• EN 61547
• EN 61000
• EN 61347
• BS EN 60598

Emergency Light Fittings

There are two basic types of emergency lighting luminaires - maintained and non-maintained. Maintained,These luminaires have the advantage of being able to be switched between the maintained function (lamp illuminated at all times) and non-maintained (lamp off until power supply fails), making them ideal for applications such as corridors, workshops and permanently illuminated emergency exit signs.The maintained luminaires also have the facility of being switched in banks of up to ten units. Non-maintained,These luminaires are only illuminated on a failure of the mains supply. Ideal for emergency exits, switchrooms and storage areas.

Specifications
Attribute Value
Maintained Non Maintained
Length 272 mm
Width 296 mm
Depth 75 mm
Duration 3h
Fitting Type Twin Spot
Wattage 2 x 3 W
Lamp Type LED
Lamp Supplied Yes
Luminosity 450 lm
Voltage Rating 230 V
Discontinued product
Related Products
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam ...
Description:
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam and pump linkage for long lifePumping handle included on all modelsSafety relief valve to prevent overloadAutomatic by-pass port to prevent over-extensionWiper seal for extended lifeThick base material with large area for increased ...
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam ...
Description:
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam and pump linkage for long lifePumping handle included on all modelsSafety relief valve to prevent overloadAutomatic by-pass port to prevent over-extensionWiper seal for extended lifeThick base material with large area for increased ...
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam ...
Description:
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam and pump linkage for long lifePumping handle included on all modelsSafety relief valve to prevent overloadAutomatic by-pass port to prevent over-extensionWiper seal for extended lifeThick base material with large area for increased ...
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam ...
Description:
Lower handle effort reduces operator fatigueFully serviceableHigh-strength beam and pump linkage for long lifePumping handle included on all modelsSafety relief valve to prevent overloadAutomatic by-pass port to prevent over-extensionWiper seal for extended lifeThick base material with large area for increased ...